Bespoke Single Phase Transformers, Single Coil
Description
- Temperature Rise :- Dependent on size
- Terminals :- Clamp or Stud, Touchproof. Flying leads on request
- Insulation Class :- B as standard for single coil construction. Higher available on request
Power Capability : | Generally up to 7.0kVA |
Voltages : | Standard up to 690V. Up to 6.6kV available |
Insulation Class : | B as standard. Higher on request |
Ambient Temp. : | Max 40°C as standard. Others on request |
Temperature Rise : | 75-80ºC as standard. Others on request |
Terminals : | Clamp or Stud, touchproof. Flying leads on request |
Options for open style
- Fuses
- Thermal protection
- Tropical varnish
Transformers can be supplied in a range of enclosures from IP22 to IP65.
Options for enclosed style
- Fuses
- Thermal protection
- MCBs & RCDs
- Plugs & sockets
- Isolators
- Meters
The following table indicates typical sizes of ‘Open Style’ transformers for various power ratings of low voltage units (<700V). Please note these may vary slightly as the specific voltage requirements determine the final transformer design.
For ‘Enclosed Style’ transformers click the box link for a dimensional drawing
Note the inclusion of some optional components may result in a size increase of the indicated enclosure type
Rating
|
A
(mm) |
B
(mm) |
C
(mm) |
T
(mm) |
Weight
(kg) |
IP22
Enclosure Name |
Click for
Drawing |
|
pdf
|
dwg
|
|||||||
50VA
|
76
|
80
|
65
|
15
|
1.0
|
WM2
|
||
75VA
|
76
|
80
|
65
|
15
|
1.0
|
WM2
|
||
100VA
|
100
|
72
|
85
|
15
|
2.0
|
WM2
|
||
150VA
|
100
|
85
|
75
|
15
|
2.0
|
WM2
|
||
200VA
|
100
|
85
|
85
|
15
|
3.5
|
WM2
|
||
250VA
|
120
|
100
|
95
|
20
|
3.5
|
WM2
|
||
300VA
|
120
|
100
|
95
|
20
|
3.75
|
WM2
|
||
400VA
|
120
|
100
|
120
|
20
|
4.25
|
WM2
|
||
500VA
|
140
|
115
|
115
|
20
|
6.0
|
WM2
|
||
650VA
|
140
|
115
|
125
|
25
|
7.25
|
WM2
|
||
750VA
|
140
|
115
|
140
|
25
|
8.0
|
WM2
|
||
1.0kVA
|
170
|
140
|
120
|
25
|
11
|
WM3
|
||
1.5kVA
|
170
|
140
|
155
|
25
|
15
|
WM3
|
||
2kVA
|
200
|
170
|
152
|
25
|
20
|
WM5
|
||
2.5kVA
|
200
|
170
|
180
|
25
|
26
|
WM5
|
||
3.0kVA
|
220
|
180
|
185
|
25
|
30
|
WM5
|
||
4.0kVA
|
235
|
200
|
220
|
25
|
35
|
FM00
|
||
5.0kVA
|
235
|
196
|
245
|
40
|
40
|
FM00
|
||
6.0kVA
|
290
|
250
|
240
|
40
|
55
|
FM0
|
||
7.0kVA
|
290
|
250
|
270
|
40
|
65
|
FM0
|
Units with voltages greater than 700V up to 6.6KV can be manufactured however the insulation requirements of these transformers will require a larger build size for the specific rating. Some units may convert to the larger dual-coil single-phase transformer construction format.
Instrument transformers manufactured with small VA ratings and low regulation levels for accuracy tend to be manufactured on frame sizes approximately 10 to 20 times their VA rating